How to Disable Thermal AI Alarm Filtering?

In some circumstances, you may wish to disable the Thermal AI based alarm filter.  Instructions are provided for WebConfig and SightMonitor I. 

Note the following:

  • Currently, the default rule for new Alarm Zones includes a filter requiring a class of human or vehicle for objects closer than the AI detection distance. This AI detection distance is shown in the Policy page (WebConfig only). 
  • To ensure that the AI Filter is disabled, check all rules for each zone, as described below.  

Disabling the AI Alarm Filter in WebConfig

  • Click Policy from the left-hand navigation to go to the Policy page
  • For each Alarm Zone, click the Edit Rule icon
  • For each rule, set AI Alarm Filtering to "Off"

  • Click Save to apply the change 

Disabling the AI Alarm Filter in SightMonitor I

  • Right click the device from camera tree and choose Set Policies
  • For each Zone that has rule-based selected, click the Alarm  Rule Editor
  •  For each alarm rule, set  AI Alarm Filtering to "NOAIFiltering", as shown

  • Click Save to save changes